Robotics CS8C Manuel d'utilisateur Page 149

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 248
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 148
CS8C © Stäubli 2009 – D28070504A
149 / 248
Chapter 6 - Operation
The robot does not go to the right place If the robot does not carry out the movements as
programmed when the "Move / Hold" key is
pressed:
check whether the controller is in "Point" manual
mode (associated indicator light on); in this case the
robot moves to the last point selected for a jog
interface.
To return to the programmed movements, exit the
"Point" mode (see paragraph 6.6).
When an application is stopped using
the "Stop" key, the "Run" indicator light
stays on.
There must be a task still being debugged.
Exit the debugging program, and then kill the task in
the task manager.
When the "1" or "2" keys are pressed,
the solenoid valves are not switched.
Check that these keys have not been assigned to
other outputs.
EVENT DIAGNOSIS
Vue de la page 148
1 2 ... 144 145 146 147 148 149 150 151 152 153 154 ... 247 248

Commentaires sur ces manuels

Pas de commentaire