Robotics COURIER Spécifications Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
Other Features 4-5
Table 4-1. Voice/Data Switch Commands.
S32
Value Voice/Data Switch Function Related Command
0 Disabled _
1 Voice/DataOriginate Mode ATD (Chapter 3)
2 Voice/DataAnswer Mode ATA (Chapter 3)
3 Redial Last Number ATDL (Chapter 3)
4 Dial Number Stored at position 0 ATDS0 (Chapter 3)
5 Auto Answer On/Off Toggle ATS0=0 or 1 (Chapter 3)
6 Reset Modem ATZ (Chapter 4)
7 Initiate Remote Digital Loopback AT&T6, S16=8 (Chapter 15)
8 Busy Out the Phone Line Toggle _
9* Execute Stored Command AT&ZC=
s
(Chapter 4)
* The modem is shipped from the factory set at S32=9. If a command string has
been stored (&ZC=
s
), the Courier sends the stored command string when you
push the Voice/Data switch. If no command string is stored, the Courier still
reports that S32=9, but actually behaves as if it is set to S32=1, Originate mode.
You can program the voice/data switch to execute a stored
command string when pressed. The following example assigns a
command string that displays the link diagnostics screen when
you press the voice/data switch.
AT&ZC=I6 <Enter>
Set the voice/data switch function to execute stored command
string by setting Register S32 to 9 with the following command:
ATS32=9 <Enter>
Note that you can reset the voice/data switch at any time to one
of the other available functions. Additionally, you can overwrite
the stored command string with a new one at any time.
Once you've stored your command string and set Register S32,
press the Voice/Data switch whenever you want the Courier to
send the command string.
Vue de la page 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 63 64

Commentaires sur ces manuels

Pas de commentaire